传感探头内的测量电子元件注塑封装及E+E特殊的镀膜保护技术,确保了EE160具有出色的长期稳定性和可靠性。
典型应用
加热、通风和空调控制
储藏室
特征
- 墙面和管道两种安装方式
- 电流或电压输出,可自由设置输出对应关系
- 经认证的BACnet MS/TP或Modbus RTU,用户可自由组态
- 可选被动温度输出
- 带温度补充
- 抗结露和污染保护
- 坚固的传感探头
- 安装便捷
- 用户可自主进行温湿度校准
- 组态软件免费
技术资料
- 测量范围
- 0...100% RH
-40...60 °C - 精度
- ±2.5% RH
±0.3 °C - 模拟输出
- 0-10V 或 4-20mA
- 数字输出
- BACnet MS/TP 或 Modbus RTU
- 被动T-输出
- 可选
- 供电
- 24 V DC