分体探头最高测量温度可达180℃,最大耐受压力可达20bar,并且能够搭配使用ISO或NPT滑动安装卡套配件,进而可以插入不同深度的油品中进行测量。使用探头安装装置可方便探头的拆卸和安装,且不中断整个设备的运行。
EE360使用了IP65高防护等级的聚碳酸酯外壳或不锈钢外壳,外壳的设计使其便于安装和维护。参数的测量值可通过两路模拟通道或一路数字通道输出,输出信号分别是4-20mA电流信号和带Modbus RTU协议的RS485数字信号或带Modbus TCP协议的以太网信号。另有报警模块作为选型,可供用户选择用于报警输出和过程状态控制。
先进的TFT彩色显示屏可同时显示所有的测量值,并提供多种错误诊断。变送器集成了数据记录功能,可将所有的测量值保存至内部存储器中。记录的数据可直接显示在设备上,也可通过USB接口实现便捷下载。
EE360可通过显示屏和按键或通过USB接口配合免费的PCS10软件对变送器进行组态(如参数选择和量程设置)和校准。
典型应用
可精密监控
- 变压器油
- 润滑油
- 液压油
- 柴油
EXTEND YOUR WARRANTY UP TO 5 YEARS WITH THE NEW
E+E CALIBRATION SERVICE PACKAGES
Our calibration service packages ensure that you are on the safe side when it comes to the accuracy and vailability of your measuring devices. Choose the right service package for your E+E product and benefit rom professional device service, calculable costs and excellent measuring accuracy in the long-term. Here you can find more detailed information.
特征
- 测量参数:水活性、温度和油品中的水含量
- TFT彩色显示屏,带按键
- 两路模拟信号输出
- 带Modbus RTU协议的RS485数字信号或带Modbus TCP协议的以太网信号
- 可存储200万条数据
- 屏幕显示错误信息或通过LED灯提示
- 错误诊断
- 分体探头长度达20米
- IP65防护等级聚碳酸酯或不锈钢外壳
- 模块化外壳便于安装和维护
- 探头耐压最高达20bar
- 插拔式探头方便安装和更换
- 两路报警输出
- G ½ ISO 或 ½ NPT连接工艺
- 球阀装置保证了在不中断变送器工作流程的情况下进行拆卸和安装
- 供电模块100...240 V AC
- 可通过显示屏或软件对变送器进行组态和校准
技术资料
- 测量范围
- 0...1 aw
0...100,000 ppm
-40...180 °C - 精度 - °测量值
- ±(0.015 + 1.5%*mv°) aw
±0.2 °C - 数字接口
- 带Modubus RTU的RS485接口
带Modbus TCP的以太网接口 - 输出信号
- 0-1/5/10V, 0/4-20mA
- 供电电源
- 8...35V DC
相关产品
下载 EE360
FAQ
Use the RS485 kit for retrofitting (order number HA010605), see the data sheet and operation manual of your specific E+E product.
The device indicates an error according to NAMUR NE43. For details, please see the user manual of your specific E+E product.
The device has one GND connection for the power supply, an analogue output GND and an interface GND, see connection diagram in the user manual. The analogue output GND and the interface GND carry only the current output resp. interface current, which results in a more stable signal compared to a mix GND connection.
Press 2x ► | 5x ◄ | 1x ▲ | 3x ◄ | 1x ▼ | 1x ► then select the "Configuration menu" and press ENTER. Scroll down to “Diagnosis”, press ENTER and scroll down to “Password protection” here you can see the previously set password.
Connect the device via the USB service interface to a PC running PCS10 Product Configuration Software and read out the communication setting.
Alternative for device with display: the display configuration menu has a section for Modbus settings (RS485, Modbus RTU) or IP settings (Ethernet, Modbus TCP) where you can see the actual setting or change it.
Connect the device via the USB service interface to a PC running PCS10 Product Configuration Software and see at the section "Log data download" for the data memory status.
Remote probe types can be retrofitted with an Ethernet interface using HA010606, see data sheet and operation manual of your specific E+E product.
The device requires a firmware update. Connect the device via the USB service interface to a PC running PCS10 Product Configuration Software and confirm the update to version 1.20 or greater.
The measured data logged by the device can only be downloaded via the USB service interface to a PC running the PCS10 Product Configuration Software.
The pluggable remote probe has a label with the serial number close to the connector. This must be the same as the serial number of the basis device. Refer to the operation manual further details.
Calibration for a specific oil is a laboratory procedure for determining the saturation curve of the oil. The saturation curve is described by two parameters (A and B). These parameters are used for setting up the moisture in oil sensor for correct calculation of the water content (ppm) out of the measured temperature and water activity (aw).
No, coating is not available for the E+E MIO sensors.
Sensor replacement is possible for the EE360 models with the ordering code including PC4 (pluggable probe). Please see the operation manual for detail and spare part code ordering guide.
Please see the cleaning instructions.
The standard scope of supply of E+E MIO sensors includes an inspection certificate according DIN EN 10204 - 3.1. For details on calibration certificates please see our white paper "Calibration and Traceability in Measuring Technology".
No, mineral transformer oils from different manufacturers are quite similar. A and B parameters are the same.