Datacenter environmental monitoring with server racks in a modern data center for precise temperature, humidity and airflow control | E+E Elektronik

Precision Humidity Sensing. Protect Equipment, Uptime and Warranties

The E+E HTS401 delivers ±0.95% RH accuracy, tool-free field calibration, and built-in condensation protection, so your humidity data holds up under scrutiny and your equipment never gets the chance to fail because of it.

Talk to a sensor expert

Why Is Humidity Control Important to You?

Humidity monitoring matters to everyone involved in a data center project, but the reasoning differs for each role.

OWNER / DATA CENTER OPERATOR

Uptime You Can Stand Behind

When equipment fails and a warranty claim gets challenged, the first question is whether the room was actually in spec. Our digital humidity sensor gives you a defensible answer, and works to keep conditions from drifting in the first place.

  • Traceable calibration certificate
  • Active protection against condensation
  • Field calibration in minutes, no tools

MECHANICAL ENGINEER

Specs that hold up in review

You're writing the Basis of Design and the Division 23 language everyone downstream builds from. The digital humidity sensor we build gives you documented accuracy your spec can stand behind.

  • ASHRAE-aligned accuracy tables
  • BIM/Revit and CAD assets available
  • IP66/NEMA 4X-rated housing

CONTROLS ENGINEER / BAS ENGINEER

A sensor your control loop can trust

A control sequence is only as stable as the data feeding it. Our digital humidity sensor outputs steady, low-drift data your sequences can actually rely on.

  • RS-485/Modbus RTU plus analog
  • Low long-term drift, fewer retunes
  • Straightforward commissioning

CONTROLS CONTRACTOR / SYSTEMS INTEGRATOR

Fewer callbacks, faster commissioning

An install that needs a follow-up visit costs you time you already budgeted somewhere else. Our digital humidity sensor swaps its sensing module in the field in minutes, no tools required.

  • Tool-free module swap, minutes per sensor
  • Pre-calibrated, digital 3.1 certificate
  • US-based support, Schaumburg, IL

MECHANICAL CONTRACTOR

Built to ship, built to last

A substitution that shows up late or fails in the field becomes your problem, not the spec writer's. Our digital humidity sensor is built for reliable lead times and field-proven durability.

  • Domestic inventory, Schaumburg, IL
  • IP66/NEMA 4X housing
  • Warranty support, US operations

Could this solution meet your project needs?

Talk to a Sensor Expert

The Cost of a Few Degrees

Data centers run on tight environmental margins. A few degrees of temperature swing or a shift in relative humidity doesn't sound like much, until it's the difference between equipment that lasts and equipment that fails early, a control loop that holds steady and one that hunts, or a project that passes commissioning without a callback and one that doesn't.

Humidity sensing sits underneath almost every one of those outcomes, and it's rarely the thing anyone questions until something's already gone wrong. An inaccurate reading doesn't just misreport conditions. It lets a cold aisle drift into condensation range without anyone knowing, it forces a control sequence to compensate for data it can't fully trust, and it turns a routine inspection into a dispute over what the room actually looked like.

The sensor is a small part of the system. Getting it wrong is not a small problem.

Open link in lightbox
The Cost of a Few Degrees

One sensor, built to answer everyone's question

Every role on this page cares about something different, uptime, spec compliance, integration, install speed, durability. The HTS401 was built to answer all five without compromise. Here's what's actually under the hood.

±0.95% RH and ±0.1°C (0.18°F), operating range −40°C to +80°C

What it means for you: The number your BMS, your spec, and your warranty documentation all rely on.

Tool-free, field-replaceable sensing module, factory pre-calibrated with a digital 3.1 inspection certificate

What it means for you: No lab downtime, no special training, no waiting on a replacement to get commissioned.

Actively protects the sensing element against chemical exposure and cleaning residue

What it means for you: Keeps accuracy intact in washdown, cleanroom, or chemically demanding environments.

Gently heats the sensing element when conditions indicate dew formation risk

What it means for you: Prevents the exact condensation event that damages equipment and voids warranties, rather than just detecting it after the fact.

RS-485 / Modbus RTU digital output, plus analog (0-5V, 0-10V, 4-20mA, 0-20mA), configurable via PCS10 software

What it means for you: Integrates into most existing BAS and control architectures without custom engineering.

Calibrated to the standard other labs measure against

EN ISO/IEC 17025 accredited laboratory, Designated Institute for humidity, dew point, air velocity, and CO2 calibration.

A quality system that's independently certified

ISO 9001, IATF 16949, and ISO 14001 certified, independently audited, not self-reported.

Matthew Nemeth

Managing Director, E+E Elektronik USA. A direct line to a person, not a ticket queue.

Matthew Nemeth | Managing Director E+E Elektronik Corporation USA
Matthew Nemeth | Managing Director E+E Elektronik Corporation USA

Go deeper, in the format you need

Whatever your reason, we can help you get there

Owner, engineer, contractor, or somewhere in between, the conversation starts the same way. Tell us about your project and we'll get you to the right person. Get expert guidance for your project.

Talk to a Sensor Expert

Please add any information that could be helpful to assist you better, such as role, experience, …

Matthew Nemeth | Managing Director E+E Elektronik Corporation USA
Matthew Nemeth | Managing Director E+E Elektronik Corporation USA
LinkedIn Logo

Live Chat

This website is using Tidio, a chat platform that connects users with the customer support of E+E Elektronik Ges.m.b.H. We are collecting email addresses/names/phone numbers only with the consent of the users, in order to start the chat. The messages and data exchanged are stored within the Tidio application. For more information, please refer to their Privacy Policy. E+E Elektronik Ges.m.b.H is not making use of these messages or data other than to follow up on users’ registered issues or inquiries. Your personal data will be processed and transmitted in accordance with the General Data Protection Regulation (GDPR).