Why Is Humidity Control Important to You?
Humidity monitoring matters to everyone involved in a data center project, but the reasoning differs for each role.

OWNER / DATA CENTER OPERATOR
Uptime You Can Stand Behind
When equipment fails and a warranty claim gets challenged, the first question is whether the room was actually in spec. Our digital humidity sensor gives you a defensible answer, and works to keep conditions from drifting in the first place.
- Traceable calibration certificate
- Active protection against condensation
- Field calibration in minutes, no tools

MECHANICAL ENGINEER
Specs that hold up in review
You're writing the Basis of Design and the Division 23 language everyone downstream builds from. The digital humidity sensor we build gives you documented accuracy your spec can stand behind.
- ASHRAE-aligned accuracy tables
- BIM/Revit and CAD assets available
- IP66/NEMA 4X-rated housing

CONTROLS ENGINEER / BAS ENGINEER
A sensor your control loop can trust
A control sequence is only as stable as the data feeding it. Our digital humidity sensor outputs steady, low-drift data your sequences can actually rely on.
- RS-485/Modbus RTU plus analog
- Low long-term drift, fewer retunes
- Straightforward commissioning

CONTROLS CONTRACTOR / SYSTEMS INTEGRATOR
Fewer callbacks, faster commissioning
An install that needs a follow-up visit costs you time you already budgeted somewhere else. Our digital humidity sensor swaps its sensing module in the field in minutes, no tools required.
- Tool-free module swap, minutes per sensor
- Pre-calibrated, digital 3.1 certificate
- US-based support, Schaumburg, IL

MECHANICAL CONTRACTOR
Built to ship, built to last
A substitution that shows up late or fails in the field becomes your problem, not the spec writer's. Our digital humidity sensor is built for reliable lead times and field-proven durability.
- Domestic inventory, Schaumburg, IL
- IP66/NEMA 4X housing
- Warranty support, US operations
The Cost of a Few Degrees
Data centers run on tight environmental margins. A few degrees of temperature swing or a shift in relative humidity doesn't sound like much, until it's the difference between equipment that lasts and equipment that fails early, a control loop that holds steady and one that hunts, or a project that passes commissioning without a callback and one that doesn't.
Humidity sensing sits underneath almost every one of those outcomes, and it's rarely the thing anyone questions until something's already gone wrong. An inaccurate reading doesn't just misreport conditions. It lets a cold aisle drift into condensation range without anyone knowing, it forces a control sequence to compensate for data it can't fully trust, and it turns a routine inspection into a dispute over what the room actually looked like.
The sensor is a small part of the system. Getting it wrong is not a small problem.

One sensor, built to answer everyone's question
Every role on this page cares about something different, uptime, spec compliance, integration, install speed, durability. The HTS401 was built to answer all five without compromise. Here's what's actually under the hood.
±0.95% RH and ±0.1°C (0.18°F), operating range −40°C to +80°C
What it means for you: The number your BMS, your spec, and your warranty documentation all rely on.

Tool-free, field-replaceable sensing module, factory pre-calibrated with a digital 3.1 inspection certificate
What it means for you: No lab downtime, no special training, no waiting on a replacement to get commissioned.

Actively protects the sensing element against chemical exposure and cleaning residue
What it means for you: Keeps accuracy intact in washdown, cleanroom, or chemically demanding environments.

Gently heats the sensing element when conditions indicate dew formation risk
What it means for you: Prevents the exact condensation event that damages equipment and voids warranties, rather than just detecting it after the fact.

RS-485 / Modbus RTU digital output, plus analog (0-5V, 0-10V, 4-20mA, 0-20mA), configurable via PCS10 software
What it means for you: Integrates into most existing BAS and control architectures without custom engineering.

Calibrated to the standard other labs measure against
EN ISO/IEC 17025 accredited laboratory, Designated Institute for humidity, dew point, air velocity, and CO2 calibration.

A quality system that's independently certified
ISO 9001, IATF 16949, and ISO 14001 certified, independently audited, not self-reported.

Matthew Nemeth
Managing Director, E+E Elektronik USA. A direct line to a person, not a ticket queue.

Whatever your reason, we can help you get there
Owner, engineer, contractor, or somewhere in between, the conversation starts the same way. Tell us about your project and we'll get you to the right person. Get expert guidance for your project.
Talk to a Sensor Expert
Please add any information that could be helpful to assist you better, such as role, experience, …