EE82

CO2 Switch for harsh environment

EE82 is optimized for harsh climate control applications such as life stock barns or storage of fruit and vegetables. The robust enclosure has been tailored for best protection of the CO2 sensing cell.

 

 

Inquire now

The air diffuses first through the filter on the front cover into the instrument enclosure and then through a second membrane filter into the CO2 sensing cell. As there is no flow through the sensing cell, this is very well protected against pollution.

The CO2 measurement is based on the Non-Dispersive Infrared (NDIR) technology. A patented auto-calibration procedure compensates for the aging of the infrared source and leads to outstanding long-term stability.

EE82 is available with measuring ranges of 0...2000, 0...5000 or 0...10000ppm. The switch threshold and hysteresis can be set with potentiometers on the printed circuit board.

The EE82 with snap-in mounting flange and M12 electrical connector allows for easiest

You want to know more about our products?
We are looking forward to help you.

Technical data EE82

  • 0...2000 ppm
    0...5000 ppm
    0...10000 ppm

    Measuring range
  • < ± (50ppm + 2% of measuring value)
    < ± (50ppm + 3% of measuring value)
    < ± (100ppm + 5% of measuring value)

    Accuracy
  • 0.7A at 50V AC
    1A at 24V DC

    Max. switching load
  • 24 V AC/DC

    Supply

You want to know more about our products?
We are looking forward to help you.

EE82 FAQ

  • What is the difference between a 2 wire and a 3 wire current output?

    Transmitter with "two-wires" technology receive the power from the process, and the signal is carry on return wire (closed current loop). With technology "three-wires" the power supply is separate from current output: 2 wires are the power supply and third carry the signal.

You want to know more about our products?