With the choice of appropriate filter cap EE07 is suitable for a variety of demanding applications. The compact design and M12 connector allow an easy system integration. For meteorology and other outdoor applications, the EE07 can be used with the optional radiation shield.
Probe setup and adjustment can be performed with an optional configuration kit.
EE07-02 is an EE07 version optimized for very low power consumption, ideal for battery powered measurement devices.
Typical Applications
You want to know more about our products?
We are looking forward to help you.
0...100% RH
-40...80 °C (-40...176 °F)
±2% RH
±0.1 °C (±0.18 °F)
digital E2 (2-wire)
Outputs3.8 - 5.5V DC
SupplyYou want to know more about our products?
We are looking forward to help you.
Datasheet | |
---|---|
EE07 Datasheet(432.89 kb) |
|
EE07-02 Datasheet(697.09 kb) |
|
Accessories(4231.46 kb) |
|
Humidity Calibration-Kit Datasheet(428.89 kb) |
Manual | |
---|---|
Calibration Kit - User Guide(1042.14 kb) |
|
Cleaning Instructions(891.89 kb) |
Support literature | |
---|---|
E2 Interface for humidity probes/modules(569.13 kb) |
|
Utilising the E2 Interface(663.63 kb) |
|
E2 Interface - specification(223.84 kb) |
Software | |
---|---|
EE-PCS Product Configuration Software(29828.69 kb) |
|
E2 interface test software for HA011001(70805.28 kb) |
Material: polycarbonate
Filter: stainless steel wire mesh
Pores size: 30 µm
Length: 33mm (1.30")
For low mechanical stress and low pollution level
For high RH / condensing environment
T range: -40...120°C (-40...248°F)
Response time t10/90: 15s
Climate control
Dryers and humidifiers
HVAC
DESCRIPTION
DESCRIPTION
DESCRIPTION
Connecting cable for remotemeasurement:
- EE07 with EE220/EE244
- EE871 with EE244
DESCRIPTION
Connecting cable for remotemeasurement:
- EE07 with EE220/EE244
- EE871 with EE244
DESCRIPTION
Connecting cable for remotemeasurement:
- EE07 with EE220/EE244
- EE871 with EE244
DESCRIPTION
DESCRIPTION
Material: PC
Filter: PTFE membrane
Pores size: 1 µm
Length: 34mm (1.34")
Very good protection against fine dust
T range: -40...80°C (-40...176°F)
Response time t10/90: 15s
Building automation
Dusty environment
Material: stainless steel
Filter: stainless steel wire mesh
Pores size: 30 µm
Length: 39mm (1.54")
For average mechanical stress andlow pollution leve
lFor high RH / condensing environment
T range: -40...120°C (-40...248°F)
Response time t10/90: 15s
Industrial process control
Clean rooms
DESCRIPTION
Certificate Type 2.1
Declaration of compliance with the order - Statement of compliance with the order.
Certificate Type 2.2
Test report - Statement of compliance with the order, with indication of results of nonspecific inspection
Certificate Type 3.1
Inspection certificate 3.1 - Statement of compliance with the order, with indication of results of specific inspection.
The maximum cable length depends on the product, clock speed and pull-up resistor, and can be up to 10m. For detail please see E2 interface for humidity probes/modules.
Only one E+E device can be connected to the E2 interface of a controller.
Transmitter with "two-wires" technology receive the power from the process, and the signal is carry on return wire (closed current loop). With technology "three-wires" the power supply is separate from current output: 2 wires are the power supply and third carry the signal.