Heated Humidity and Temperature Probe for Meteorology

Open Link in LightboxEE260 humidity and temperature probe
  • Service
  • Humidity
  • Temperature

EE260

The EE260 humidity and temperature probe with heated humidity sensing element and probe heating delivers precise and reliable measuring results even at high humidity conditions.

  • EE260 humidity and temperature probe

    EE260 humidity and temperature probe

  • EE260 humidity and temperature probe with radiation shield

    EE260 humidity and temperature probe with radiation shield

  • Humidity and temperature sensing element with the E+E proprietary sensor coating

    Humidity and temperature sensing element with the E+E proprietary sensor coating

  • NEW! Now with Extended Warranty Option

    NEW! Now with Extended Warranty Option

    Measuring Performance

    The EE260 humidity and temperature probe has a dual heating system (sensing element and probe heating). This prevents condensation on the RH sensing element, the sensing head and the filter cap. The probe therefore provides precise and reliable measurement results even in the case of permanent high humidity.

    Another benefit of the dual heating system is the very short response time and a fast recovery after condensation.

    The E+E sensor coating improves the long-term stability and service life in dusty and corrosive environments.

    Compact and Robust

    The innovative enclosure of the EE260 combines a heated humidity sensing head and an additional temperature sensing element in a single probe.

    Due to its compact design, the probe is compatible with commercially available rotationally symmetric sensor radiation shields.

    The robust IP67 enclosure made of UV- and heat-resistant elastomer protects the internal electronics from environmental influences and mechanical damage.

    Analogue and Digital

    The EE260 probe provides the measured data simultaneously on two freely configurable voltage outputs and via the RS485 interface (Modbus RTU).

    Based on the measured humidity and temperature values, the EE260 calculates further humidity-related quantities such as the dew point temperature, absolute humidity or mixing ratio.

    Typical Applications

    • Meteorological weather stations
    • Weather warning systems (road traffic, airports)
    • Detection of icing hazard

    EXTEND YOUR WARRANTY UP TO 5 YEARS WITH THE NEW 
    E+E CALIBRATION SERVICE PACKAGES

    Our calibration service packages ensure that you are on the safe side when it comes to the accuracy and vailability of your measuring devices. Choose the right service package for your E+E product and benefit rom professional device service, calculable costs and excellent measuring accuracy in the long-term. Here you can find more detailed information.

    NEW! Now with Extended Warranty Option

    Key Features

    • Excellent measurement performance and high accuracy in the high humidity range
    • Compact, robust IP67 enclosure
    • Heated RH sensing element and heated sensing head
    • Two freely configurable voltage outputs
    • Integrated T sensing element
    • RS485 interface with Modbus RTU protocol
    • Short response time and a fast recovery after condensation
    • Calculation of all relevant humidity related quantities
    • E+E sensor coating against pollution and corrosion for best long term stability
    • Compatible with rotationally symmetric sensor radiation shields

    Technical data

    Measuring range - Humidity
    0...100% RH
    Accuracy - Humidity
    ±1.3% RH
    Measuring range - Temperature
    -60...60 °C (-76...140 °F)

    Accuracy - Temperature
    analogue: 0.15 °C (0.27°F)
    digital: 0.1 °C (0.18°F)
    Digital interface
    RS485 with Modbus RTU
    Analogue Outputs
    0-1/2.5/5/10V
    Supply
    7 - 30 V DC