E+E Product Finder

Filter

11 Products out of 63

AVS701

Highly Accurate Air and Gas Velocity Sensor for Industrial Applications

  • Air velocity measuring range 0...2 m/s (0...400 ft/min) 0...15 m/s (0...3 000 ft/min) 0...40 m/s (0...8 000 ft/min)
  • Accuracy air velocity 0.06...2 m/s: ±0.03 m/s 0.15...10 m/s: ±(0.1 m/s + 1% of mv) 0.2...40 m/s: ±(0.2 m/s + 1% of mv)
  • Temperature measuring range -40...+140 °C (-40...+284 °F)
  • Accuracy (T) ±0.5 °C (±0.9 °F)
  • Power supply class III 24 V DC ±20%
  • Protection rating IP65 / NEMA 4X
AVS701

EE072

Humidity and Temperature Probe with Digital Interface

  • Measuring range humidity 0…100 % RH
  • Accuracy humidity ± 1.3 % RH
  • Measuring range temperature -40…80 °C (-40…176 °F)
  • Accuracy temperature ± 0.1 °C at 20 °C
  • Output Modbus RTU or CANopen
  • Supply 10…28 V DC
EE072

EE074

Temperature Probe with Modbus RTU

  • WORKING RANGE -70…105 °C (-94…221 °F)
  • ACCURACY ± 0.1 °C (± 0.18 °F)
  • OUTPUT Modbus RTU
  • SUPPLY 24 V DC
EE074

EE211

Humidity and Temperature Sensor for Continuous High Humidity

  • Measuring range - Humdity 0...100% RH
  • Measuring range Temperature -40...+60 °C (-40...+140 °F)
  • Sensing Element E+E proprietary coating heated for high humidity operation
  • Analogue outputs 0-5V / 10 V 0-20mA / 4-20 mA
  • Digital Interface Modbus RTU
  • Accuracy - Humdity -5...+30 °C (23...86°F) / ±(1.3+0.007*mv°)% RH)
  • Accuracy Temperature at 20°C (68°F)|±0.1 °C
EE211

EE431

Duct and Immersion Temperature Sensor

  • Measuring Range: Duct sensor (probe tip) -40...+110 °C (-40...230 °F)
  • Measuring Range: immersion well (probe tip) -40...+130 °C (-40...+266°F)
  • Accuracy active output ±0.1 °C (±0.18 °F)
  • Analogue output 0-10 V or 4-20 mA (2-wire)
  • Digital interface RS485 with Modbus RTU
  • Protection class IP65 / NEMA 4X
  • Supply 24 V AC/DC
EE431

EE600

Differential Pressure Sensor

  • Measuring range I: 0...250 / 500 / 750 / 1000 Pa ±250 / ±500 / ±750 / ±1000 Pa
  • Measuring range II: 0...2500 / 5000 / 7500 / 10000 Pa ±2500 / ±5000 / ±7500 / ±10000 Pa
  • Accuracy - *Full Scale (1000 Pa or 10000 Pa) ±0.5 % FS*
  • Overload limits 0...1000 Pa /±1000 Pa ± 10000 Pa 0...10000 Pa / ±10000 Pa ± 80000 Pa
  • Analog outputs - *selectable with DIP switches *0-5 V or 0-10 V *0-20 mA or 4-20 mA 4-20 mA (2-wire)
  • Digital output Modbus RTU
EE600

EE610

Low Differential Pressure Sensor

  • Measuring range 0...25 / 50 / 75 / 100 Pa
  • Accuracy - *Full Scale ±0.5 Pa = 0.5 % FS*
  • Working range - temperature -20...+60°C (-4...140°F)
  • Feature Auto-zero function
  • Overload limit ± 7000 Pa
  • Analog outputs 0-5V / 0-10 V 0-20mA / 4-20mA
  • Digital interface Modbus RTU
  • Power Supply 15 - 35 V DC or 24 V AC ±20 %
EE610

EE820

CO₂ Sensor for Demanding Applications

  • Measuring range CO₂ 0...2000 ppm 0...5000 ppm 0...10000 ppm
  • Accuracy CO₂ at 25 °C (77 °F) and 1013 mbar (14.7 psi) ± (50ppm + 2% of measuring value) ± (50ppm + 3% of measuring value) ± (100ppm + 5% of measuring value)
  • Output analogue 0-10 V or 4-20 mA
  • Supply 24V AC/DC
EE820

EE872

Modular Probe for CO₂, Humidity, Temperature and Ambient Pressure

  • Measuring Range CO₂ 0…2000 ppm 0…5000 ppm 0…10000 ppm 0…3 % (30000 ppm) 0…5 % (50000 ppm)
  • Accuracy CO₂ - * mv – measured value ± (50 ppm + 2 % mv*) ± (50 ppm + 3 % mv*) ± (100 ppm + 5 % mv*) ± (1.5 % from full scale + 2 % mv*) ± (1.5 % from full scale + 2 % mv*)
  • Measuring range Relative Humidity 0…95 % RH (non condensing)
  • Accuracy Relative Humidity at 25 °C (77 °C) and 20...80% RH typ. ± 3 % RH
  • Measuring range Pressure 700…1100 mbar (10.15...15.95 psi)
  • Accuracy Pressure at 25 °C typ. ± 2 mbar
  • Measuring range Temperature -40…60 °C (-40...140 °F)
  • Accuracy Temperature at 5…60 °C (41…140 °F) typ. ± 0.5 °C (± 0.9 °F)
  • Output analogue 0-5V / 10 V and 0/4-20 mA
  • Output digital Modbus RTU
  • Supply 15-35 VDC (current) 12-30 VDC (voltage / RS485)
EE872

HTP201

Humidity and Temperature Probe with Analogue Outputs

  • Measuring range - Humidity 0...100 %RH
  • Accuracy - Humidity ±2.5 %RH
  • Measuring range - Temperature -40...80 °C (-40...176 °F)
  • Accuracy - Temperature ±0.3 °C (±0.54 °F)
  • Analogue output - voltage 0 - 1/5/10 V
  • Analogue output - current 4 - 20 mA
HTP201

HTS401

Modular Humidity and Temperature Sensor for Demanding Climate Control

  • Measuring range Humdity 0...100% RH
  • Accuracy Humdity -15...40 °C <90% RH ±(0.95+0.0013*mv)% RH
  • Measuring range Temperature (wall mount) -40...60 °C (-40...140°F)
  • Measuring range Temperature (duct mount) -40...80 °C (-40...176°F)
  • Accuracy Temperature ±0.1 °C (0.18°F)
  • Accuracy Humidity ±0.95 % RH
  • Analogue outputs 0-5V, 0-10V, 4-20mA, 0-20mA (3-wire)
HTS401
LinkedIn Logo

Live Chat

This website is using Tidio, a chat platform that connects users with the customer support of E+E Elektronik Ges.m.b.H. We are collecting email addresses/names/phone numbers only with the consent of the users, in order to start the chat. The messages and data exchanged are stored within the Tidio application. For more information, please refer to their Privacy Policy. E+E Elektronik Ges.m.b.H is not making use of these messages or data other than to follow up on users’ registered issues or inquiries. Your personal data will be processed and transmitted in accordance with the General Data Protection Regulation (GDPR).