E+E Product Finder
63 Products
EE772
Multifunctional Flow Sensor for Compressed Air and Gases
- Measured values standardized volumetric flow, mass flow, standardised flow, temperature, consumption
- Measuring range 0.5 - 200 Nm/s (100…39370 SFPM)
- Accuracy ±1.5 % of the measured value
- Pipe diameter DN40 up to DN80 (1 1/2" - 3")
- Outputs 0-10 V, 0/4-20 mA, Pulse, Switch, Modbus RTU or M-Bus
- Supply 18 - 30 V AC/DC
EE776
Insertion Flow Sensor for Compressed Air and Gases
- Measured values standardized volumetric flow, mass flow, standardised flow, temperature, consumption
- Measuring range 0.5…100 m/s (98…19685 SFPM) and 0.5…200 m/s (98…39370 SFPM)
- Accuracy ±1.5 % of the measured value
- Pipe diameter DN50 up to DN700 (2" to 28")
- Outputs 0-10 V, 0/4-20 mA, Pulse, Switch, Modbus RTU or M-Bus
- Supply 18 - 30 V AC/DC
EE820
CO₂ Sensor for Demanding Applications
- Measuring range CO₂ 0...2000 ppm 0...5000 ppm 0...10000 ppm
- Accuracy CO₂ at 25 °C (77 °F) and 1013 mbar (14.7 psi) ± (50ppm + 2% of measuring value) ± (50ppm + 3% of measuring value) ± (100ppm + 5% of measuring value)
- Output analogue 0-10 V or 4-20 mA
- Supply 24V AC/DC
EE850
CO₂ and Temperature Sensor for Duct Mounting
- Measuring range CO₂ 0...2000 ppm 0...10000 ppm
- Accuracy CO₂ - *mv - measured value < ± (50 ppm +2% of mv*) < ± (100 ppm +5% of mv*)
- Measuring range Temperature -20...60 °C (-4...140 °F)
- Accuracy Temperature ±0.3 °C (±0.54 °F)
- Output analogue 0-5 / 10 V or 4-20 mA
- Output digital Modbus RTU
- Supply 24 V AC/DC
EE872
Modular Probe for CO₂, Humidity, Temperature and Ambient Pressure
- Measuring Range CO₂ 0…2000 ppm 0…5000 ppm 0…10000 ppm 0…3 % (30000 ppm) 0…5 % (50000 ppm)
- Accuracy CO₂ - * mv – measured value ± (50 ppm + 2 % mv*) ± (50 ppm + 3 % mv*) ± (100 ppm + 5 % mv*) ± (1.5 % from full scale + 2 % mv*) ± (1.5 % from full scale + 2 % mv*)
- Measuring range Relative Humidity 0…95 % RH (non condensing)
- Accuracy Relative Humidity at 25 °C (77 °C) and 20...80% RH typ. ± 3 % RH
- Measuring range Pressure 700…1100 mbar (10.15...15.95 psi)
- Accuracy Pressure at 25 °C typ. ± 2 mbar
- Measuring range Temperature -40…60 °C (-40...140 °F)
- Accuracy Temperature at 5…60 °C (41…140 °F) typ. ± 0.5 °C (± 0.9 °F)
- Output analogue 0-5V / 10 V and 0/4-20 mA
- Output digital Modbus RTU
- Supply 15-35 VDC (current) 12-30 VDC (voltage / RS485)
EE8915
CO₂ Sensor for Railway Applications
- Measuring range 0...2000 ppm 0...5000 ppm 0...10000 ppm
- Accuracy - *mv - measured value <± (50 ppm +2% of mv) <± (50 ppm +3% of mv) <± (100 ppm +5% of mv)
- Outputs 0-5 / 10V and 0 / 4-20mA
- Supply 10-35 V DC
EE894
Digital Sensor Module for CO₂, Temperature, Humidity and Ambient Pressure
- Measuring range CO₂ 0...2000 ppm 0...5000 ppm 0...10000 ppm
- Accuracy CO₂ at 25 °C (77 °F) and 1013 mbar (14.69 psi) ±(50 ppm +2% of mv) ±(50 ppm +3% of mv) ±(100 ppm +5% of mv)
- Measuring range Relative Humidity 0…95 % RH (non condensing)
- Accuracy Relative Humidity at 25 °C (77 °C) and 20...80% RH typ. ± 3 % RH
- Measuring range Pressure 700…1100 mbar (10.15...15.95 psi)
- Accuracy Pressure at 25 °C (77 °C) and 20...80% RH typ. ± 2 mbar
- Measuring range Temperature -40…60 °C (-40...140 °F)
- Accuracy Temperature at 25 °C (77 °F) typ. ± 0.5 °C (± 0.9 °F)
- Digital interface I²C or E2
- Supply 4.75-7.5V DC
EE895
Miniature Sensor Module for CO₂, Temperature and Ambient Pressure
- Measuring range CO₂ 0...2000 ppm 0...5000 ppm 0...10000 ppm
- Accuracy CO₂ at 25 °C (77 °F) and 1013 mbar (14.69 psi) ±(50 ppm +2% of mv) ±(50 ppm +3% of mv) ±(100 ppm +5% of mv)
- Measuring range Pressure 700…1100 mbar (10.15...15.95 psi)
- Accuracy Pressure at 25 °C (77 °C) typ. ± 2 mbar
- Measuring range Temperature -40…60 °C (-40...140 °F)
- Accuracy Temperature at 25 °C (77 °F) typ. ± 0.5 °C (± 0.9 °F)
- Digital interface I²C or UART
- Supply 3.3 - 5V DC
EE99-1
Humidity and Temperature Module for OEM Applications
- Measuring range 0...100% RH -50...180°C (-58...356°F), short term up to 200°C (392°F)
- Accuracy ±1.3% RH T-passive (Pt100 DIN A or Pt1000 DIN A)
- Outputs RH: 4-20mA (3-wire) T: passive (3-wire connection)
- Supply 10-35V DC or 10-28V AC
HC103M2
Very Fast Humidity Sensor for Radiosondes
- Nominal capacitance C0 (at 30°C / 86°F) 160 ± 40 pF
- Sensitivity 0.55 pF / % RH
- Working range humidity 0...100% RH
- Working range temperature -80...60 °C (-112...140 °F)
- Linearity error (0...98% RH) < ± 2% RH
- Response time t63 < 3 s at 23°C /< 15 s at -20°C
HMC03M
Heated Humidity Sensing Element for Radiosondes and Weather Balloons
- Nominal capacitance C0 (at 30 °C / 86 °F) 120 ± 40 pF
- Sensitivity (for C0 = 120 pF, in average) 0.41 pF / % RH
- Response time t63 (see Graph for details) < 8 sec. at -30 °C (-22 °F) < 11 sec. at -40 °C (-40 °F)
- Working range temperature -80...60 °C (-112...140 °F)
- Working range humidity 0...100 % RH
- Linearity (0...98% RH) < ± 2 % RH
HTE301
Cost Optimised Digital Sensing Element for Humidity and Temperature
- Measuring range 0...100 % RH -40...125 °C (-40...257 °F)
- Accuracy up to ±1.8 % RH (incl. hysteresis) up to ± 0.2 °C (0.36 °F)
- Response time humidity (typ. τ63% ) 5s
- Response time temperature (min. τ63%) 2s
- Digital interface I²C
- Supply Voltage 2.35 - 3.6 V
- Dimensions (L x W x H) 2.5 x 2.5 x 0.9 mm