EE451
Wall Mounted Temperature Sensor
- Operating temperature -40…70°C (-40…158 °F)
- Accuracy active output ±0.3 °C (±0.54 °F) ±0.1 °C (±0.18 °F) (TT2 version)
- Analogue output 0-10 V or 4-20 mA
- Digital interface RS485 with Modbus RTU
- Protection class IP65 / NEMA 4X
- Supply 24 V AC/DC
EE461/EE462
Cable Temperature Sensor
- Operating temperature - EE461 -30...105 °C (-22...221 °F)
- Operating temperature - EE462 - Glass fibre 0...350 °C (32...662 °F)
- Operating temperature - EE462 - Silicone -60...180 °C (-76...356 °F)
- Protection class IP67 / NEMA 4
- Insulation resistance typ. > 100 MΩ at 20 °C (68 °F)
EE471
Temperature Sensor with Remote Probe
- Operating temperature remote probe: -30...105 °C (-22...221 °F) electronics: -30...70 °C (-22...158 °F)
- Accuracy active output ±0.3 °C (±0.54 °F)
- Analogue output 0-10 V or 4-20 mA
- Digital interface RS485 with Modbus RTU
- Protection class IP65 / NEMA 4X
- Supply 24 V AC/DC
EE576
Probe for Very Low Air Velocity
- Measuring range 0...2m/s (0...400ft/min) 0...1m/s (0...200ft/min)
- Accuracy 0.2... 1m/s: ±(0.05m/s (10ft/min) +2% of MV) 0,2... 2m/s: ±(0.08m/s (16ft/min) +4% of MV)
- Outputs 0-5V or 0-10V
- Supply 10-19V DC or 19-29V DC
EE600
Differential Pressure Sensor
- Measuring range I: 0...250 / 500 / 750 / 1000 Pa ±250 / ±500 / ±750 / ±1000 Pa
- Measuring range II: 0...2500 / 5000 / 7500 / 10000 Pa ±2500 / ±5000 / ±7500 / ±10000 Pa
- Accuracy - *Full Scale (1000 Pa or 10000 Pa) ±0.5 % FS*
- Overload limits 0...1000 Pa /±1000 Pa ± 10000 Pa 0...10000 Pa / ±10000 Pa ± 80000 Pa
- Analog outputs - *selectable with DIP switches *0-5 V or 0-10 V *0-20 mA or 4-20 mA 4-20 mA (2-wire)
- Digital output Modbus RTU
EE610
Low Differential Pressure Sensor
- Measuring range 0...25 / 50 / 75 / 100 Pa
- Accuracy - *Full Scale ±0.5 Pa = 0.5 % FS*
- Working range - temperature -20...+60°C (-4...140°F)
- Feature Auto-zero function
- Overload limit ± 7000 Pa
- Analog outputs 0-5V / 0-10 V 0-20mA / 4-20mA
- Digital interface Modbus RTU
- Power Supply 15 - 35 V DC or 24 V AC ±20 %
EE650
Air Velocity Sensor for HVAC Applications
- Measuring range - user selectable 0...10 m/s (0...2000 ft/min) 0...15 m/s (0...3000 ft/min) 0...20 m/s (0...4000 ft/min)
- Accuracy at 20 °C (68 °F), 45 % RH, 1013 hectopascal 0.2...10 m/s ±(0.2 m/s + 3 % of mv) 0.2...15 m/s ±(0.2 m/s + 3 % of mv) 0.2...20 m/s ±(0.2 m/s + 3 % of mv)
- Response time - user selectable typ. 4 sec or typ. 1 sec.
- Output Analogue 0-10 V and 4-20 mA
- Output Digital Modbus RTU
- Supply 24 V AC/DC
EE660
Low Air Velocity Sensor
- Measuring range selectable by jumper 0...1 m/s (0...200 ft/min) 0...1.5 m/s (0...300 ft/min) 0...2 m/s (0...400 ft/min)
- Accuracy at 20 °C (68 °F), 45 % RH, 1013 hectopascal 0.15...1 m/s ±(0.04 m/s + 2 % of mv) 0.15...1.5 m/s ±(0.05 m/s + 2 % of mv) 0.15...2 m/s ±(0.06 m/s + 2 % of mv)
- Response time(at constant temperature) typ. 4 sec or typ. 1 sec.
- Output analogue - selectable 0-10 V and 4-20 mA
- Output digital Modbus RTU
- Supply 24 V AC/DC
EE671
HVAC Air Velocity Probe
- Measuring range 0...5m/s (0...1000ft/min) 0...10m/s (0...2000ft/min) 0...15m/s (0...3000ft/min) 0...20m/s (0...4000ft/min)
- Accuracy 0.5... 5m/s: ±(0.2m/s (40ft/min) +3% of MV) 1... 10m/s: ±(0.3m/s (60ft/min) +4% of MV) 1... 15m/s: ±(0.35m/s (70ft/min) +5% of MV) 1... 20m/s: ±(0.4m/s (80ft/min) +6% of MV)
- Outputs 0-1/5/10 V (max. 1 mA) Modbus RTU
- Supply 10-29V DC SELV
EE680
Air Velocity and Temperature Sensor for Laminar Flow
- MEASURING RANGE – AIR VELOCITY 0...2 m/s (0...400 ft/min)
- ACCURACY – AIR VELOCITY (mv = measured value) 0.1...2 m/s (20...400 ft/min): ± (0.5 % of mv + 0.05 m/s)
- MEASURING RANGE – TEMPERATURE -20...70 °C (-4...158 °F)
- ACCURACY – TEMPERATURE ±0.5 °C (±0.9 °F)
- ANALOG OUTPUTS 0-5 V / 0-10 V or 0-20 mA / 4-20 mA (3-wire)
- DIGITAL OUTPUT Modbus RTU
EE741
Inline Flow Sensor for Compressed Air and Gases
- Measured values standardized volumetric flow, mass flow, standardised flow, temperature, consumption
- Pipe diameter DN15 / DN20 / DN25 DN32 / DN40 / DN50
- Measuring range - flow DN15: 0.2 - 76.3 Nm³/h (0.12 - 44.88 SCFM) DN20: 0.4 - 135.6 Nm³/h (0.24 - 79.77 SCFM) DN25: 0.6 - 212 Nm³/h (0.36 - 124.71 SCFM)
- Measuring range - flow DN32: 0.9 - 347.4 Nm³/h (0.52 - 202.06 SCFM) DN40: 1.4 - 542.8 Nm³/h (0.81 - 315.71 SCFM) DN50: 2.2 - 848.2 Nm³/h (1.22 - 493.35 SCFM)
- Accuracy - flow (*measured value) ±(3 % of mv* + 0.3% of full scale)
- Measuring range - temperature -20...60 °C (-4...140 °F)
- Accuracy - temperature ± 0.7 °C (1.26 °F)
- Outputs 0/4-20 mA, Pulse, Switch, Modbus RTU, M-Bus or IO-Link
- Supply 18 - 30 V DC
EE771
Flow Sensor for Compressed Air and Gases
- Measured values standardized volumetric flow, mass flow, standardised flow, temperature, consumption
- Measuring range 0.5 - 200 Nm/s (100…39370 SFPM)
- Accuracy ±1.5 % of the measured value
- Pipe diameter DN15 up to DN50 (1/2" - 2")
- Outputs 0-10 V, 0/4-20 mA, Pulse, Switch, Modbus RTU or M-Bus
- Supply 18 - 30 V AC/DC