E+E Product Finder
63 Products
HTE501
Digital Humidity and Temperature Sensor
- Humidity range 0...100 % RH -40...135 °C (-40...275 °F)
- Accuracy humidity up to ±1.8 % RH (incl. hysteresis) up to ± 0.2 °C (0.36 °F)
- Digital interface I²C
- Supply 2.35 - 3.6 V
- Temperature range -40...135 °C
- Dimensions (L x W x H) 2.5 x 2.5 x 0.9 mm
HTP201
Humidity and Temperature Probe with Analogue Outputs
- Measuring range - Humidity 0...100 %RH
- Accuracy - Humidity ±2.5 %RH
- Measuring range - Temperature -40...80 °C (-40...176 °F)
- Accuracy - Temperature ±0.3 °C (±0.54 °F)
- Analogue output - voltage 0 - 1/5/10 V
- Analogue output - current 4 - 20 mA
HTP501
Digital Humidity and Temperature Probe up to 120 °C (248 °F)
- Measuring range - Humidity 0…100 % RH
- Accuracy - Humidity ± 1.3 %RH
- Measuring range - Temperature -40…120 °C (-40…248 °F)
- Accuracy - Temperature ± 0.1 °C at 20 °C
- Output Modbus RTU
- Supply 8…35 V DC
HTS201
Room Sensor for Relative Humidity and Temperature
- Measuring range - Humidity 0...100 % RH, non-condensing
- Accuracy - Humidity ±(2 + 0.003 * mv) % RH mv = measured value
- Measuring range - Temperature -30...+60 °C (-22...+140 °F)
- Accuracy - Temperature ±0.25 °C (±0.14 °F), voltage output / RS485 ±0.38 °C (±0.21 °F), current output
- Output analogue 0-10 V or 4-20 mA
- Output digital RS485 (Modbus RTU)
- Power supply 15-35 V DC or 24 V AC ±20 %
HTS401
Modular Humidity and Temperature Sensor for Demanding Climate Control
- Measuring range Humdity 0...100% RH
- Accuracy Humdity -15...40 °C <90% RH ±(0.95+0.0013*mv)% RH
- Measuring range Temperature (wall mount) -40...60 °C (-40...140°F)
- Measuring range Temperature (duct mount) -40...80 °C (-40...176°F)
- Accuracy Temperature ±0.1 °C (0.18°F)
- Accuracy Humidity ±0.95 % RH
- Analogue outputs 0-5V, 0-10V, 4-20mA, 0-20mA (3-wire)
HTS801
Humidity and Temperature Sensor for High Humidity and Chemically Polluted Conditions
- Measuring range - Humidity 0...100 % RH
- Measuring range - Temperature -80...+180 °C (-112...+356 °F)
- Measuring range - pressure-tight probe 0.01...300 bar (0.15...4350 psi)
- Analogue output 0-1 V / 0-5 V / 0-10 V 0-20 mA / 4-20 mA
- Digital interface RS485 with Modbus RTU Ethernet-PoE with Modbus TCP
Humidity Calibration Kit
For a Quick Humidity Check
- humidity value in %RH ... accuracy at 23 °C (73.4 °F) 0% RH ... ±0.3% RH 5% RH ... ±0.5% RH 10% RH ... ±0.5% RH 20% RH ... ±0.5% RH 35% RH ... ±0.5% RH
- humidity value in %RH ... accuracy at 23 °C (73.4 °F) 50% RH ... ±0.9% RH 65% RH ... ±0.9% RH 80% RH ... ±1.2% RH 95% RH ... ±1.2% RH
Humor 20
High Precision Humidity Calibrator
- Operating range 10...95% RH
- Accuracy 0.3 - 0.9% RH
- Stabilisation time < 3 min/measuring point
- Supply 90...230V AC
MOP301
Digital Moisture in Oil Immersion Probe up to 120 °C (248 °F)
- Measuring Range 0...1 aw -40...120 °C (-40...248 °F)
- Accuracy ±0.02 aw ±0.15 °C
- Digital Interface RS485 with Modbus RTU
- Supply 8-35 V DC
Omniport 40
Multifunctional Hand-Held Meter
- Power Supply 4x AA rechargeable NiMH batteries
- Connections 2x 5-pin M12 connection
- Internal memory Up to 1 million measuring points
- Environmental Conditions (operation) -5...+50 °C (+23...+122 °F); 0...85 % RH non-condensing
- Dimensions 170 x 78 x 38 mm (6.69 x 3.07 x 1.50")
- Protection rating IP67
Sigma 05
Modular Sensor Platform
- MAX. NUMBER OF SENSINGS PROBES 3
- MAX. NUMBER OF MEASURANDS (* 2 ON THE ANALOGUE OUTPUTS / 3 ON THE DISPLAY) 5
- PROBE INTERFACE RS485
- PROTOCOL Modbus RTU
- ANALOG OUTPUTS 0 - 1 V / 2.5 V / 5 V / 10 V 0 / 4 - 20 mA (3-wire)
- ACCURACY OF ANALOGUE OUTPUTS AT 20 °C (68 °F) (*FS = FULL SCALE) 0.02 % FS for 0 - 10 V and 0 - 20 mA
- PROTECTION RATING IP65 / NEMA 4
TDS501
Dew Point Sensor down to -70 °C Td (-94 °F Td)
- Measuring range -70...+60 °C (-94...+140 °F)
- Accuracy ±2 °C (±3.6 °F)
- Pressure Rating 80 bar (1,160 psi)
- Digital interface RS485
- Protection rating IP65